Shanghai Rotorcomp Screw Compressor Co., Ltd.
  • Rotary Screw Compressor Historiese bekende vervaardiger wat kwaliteitskompressor lewer, olievrye kompressor, hoëdruk kompressor in ISO, TUV, CE-sertifikate met goeie prys, 5 jaar waarborg, gepatenteerde unieke ontwerp, meer energiebesparende, betroubare kompressorsisteem vir al Rotary Screw Compressor
  • Olievrye Kompressor Sjanghai rotorcomp skroef kompressor bied 100% skoon olie gratis lug kompressor wat gemaak kan word in die lug afgekoel en water afgekoel, kan ons aanpas volgens die spesiale versoeke, en OEM diens ... Olievrye Kompressor
  • Lugbehandelingstelsels Na-verwerking toerusting van compressorISO, CE, TUV, ASME standaard vervaardiger die vervaardiging van kwaliteit Koel lug droog, droogmiddel lug droog, presiese pyp filter van 1micron tot 0.001micron, aktiewe motor ... Lugbehandelingstelsels
  • Diesel beweegbare skroef kompressor Diesel roerende skroef kompressorReliable diesel draagbare skroef kompressor vervaardiger produseer kwaliteit diesel skroef kompressor van 50cfm - 1600cfm @ 100psi-500psi in ISO, TUV, CE sertifikate met goeie p ... Diesel beweegbare skroef kompressor
  • Skroef Air End SCREW AIR ENDWorld-top Rotorcomp kompakte lugskroef kompressor met die beste doeltreffend in kleiner demensie in ISO, TUV sertifikate, 5 jaar waarborg. Rotor Comp olie-ingespuit skroef lug eindig skep die hart ... Skroef Air End
CONATCT
Tel: + 86-021-67150020
Faks: + 86-021-67150020
Add: No.28 Minta Road, Songjiang Distrik Sjanghai, China
code

Algemene elektriese versaking en oorsake

Hierdie foutoorsig
Fout stop wat veroorsaak word deur die eksterne dele van controllers kan verwyder word deur hierdie HIERDIE Fout of GESKIEDENIS FOUT te keur. Die metode word hieronder getoon:
Algemene elektriese versaking en oorsake



FAILURE

CAUSES

MEASUREMENT TO TAKE

Air Exhaust Temperature too high

Bad vent condition, Oil lacking etc.

Check the vent condition and lubricant amount etc.

Temperature Sensor Failure

Cable off or PT1OO damaged

Checking the wiring and PT100

Over Pressure

The pressure too high or the pressure sensor failure

Check the pressure and the pressure sensor

Pressure Sensor Failure

Cable off, Sensor damaged or the cable connected reversed

Check the wiring and sensor transformer

Water Lacking

Water Pressure switch damaged

Check the water pressure switch

Phase Lacking

Power phase lacking or the Contactor terminal damaged

Check the power and contactors

Overloaded

Voltage too low, tubes blocked, Bearing Wear off or other mechanical failure or wrong set data etc.

Check the set data, Voltage, bearings, tubes and other mechanical systems.

Unbalance

Power unbalance, Contactor damaged or the internal open of the motor

Check the power, contactors and the motor

Rotor Lock

Voltage too low, tubes blocked, Bearing Wear off or other mechanical failure or wrong set data etc.

Check the set data, Voltage, bearings, tubes and other mechanical systems.

Short Circuit

Wrong Wiring, Incorrect Data setting etc.

Checking the wiring and set the data correctly

Wrong Phase Sequence

Reversed Phase sequence or phase off

Check the wiring

Fan stopped

Fan damaged, Contactor damaged, no control output

Check the wiring and control output

Overload or Rotor locking during starting process

Host start time set to a value less than the star angel time delay

Reset the host starting time to be longer than star angel delay + Load delay time

The main Contactor activate time to time

The emergency button loose

Check the wiring